Main - Plumbing - Bathroom - Sloan - Flushometer Variations - Vacuum Breakers And Flush Connections
| Most Sloan flushometer valves are furnished with a Vacuum
Breaker Flush Connection to prevent back siphonage. Sloan V-600-A and V-500-A Vacuum Breakers are designed and tested to ASSE Standard 1001. Vacuum Breakers are required by code by All United States and many international plumbing codes when the valve is connected to a potable water supply. When valves are installed on a non-potable water supply system vacuum breakers are not required. |
||||||
| To furnish the valve less Vacuum breaker specify the "XYV" Variation. | ||||||
| Offset Vacuum Breaker High Rough-in valves (model 115 & 116 and BPW-1000) can be furnished with an offset vacuum breaker. |
"O" Variation | |||||
|
||||||
|
||||||
| If
a valve model is required with a different diameter Vacuum Breaker or inlet tube use the following variations; |
||||||
| "T" Variation | 1-1/2" Flush Connection | |||||
| "U" Variation | 1-1/4" Flush Connection | |||||
| "V" Variation | 1" Flush Connection | |||||
| "W" Variation | 3/4" Flush connection | |||||
| Trap Primers | "TP" Variation | |||||
| Vacuum Breakers can be provided with a Trap Primer Fitting - See VBF-72-A Trap Primer | ||||||